[Done][Last][Next]
Text (12 of 23) in How to Specify and Install GRANEX


Joint Treatment

17-12

To download a high resolution version of this drawing for printing, click here.




All joints should be caulked using a high quality color-matched sealant such as that supplied, on request by GRAHAM FRP Composites or its distributors. Sealants should be non-yellowing, low in dirt pick- up, resistant to ultra-violet degradation, non-hardening and of low modulus. Most silicones, urethanes and polysulphides are suitable. Consult caulking manufacturer's literature or a technical sales representative before installation. A minimum joint gap should be 1/4" (6.4 mm) between panels up to 12 ft (3.7 m) in length. Most caulking manufacturers recommend a joint width to sealant depth ratio of 2:1 (minimum).

For optimum results, it is recommended that caulking be carried out by a recognized caulking contractor. Every precaution should be taken to protect the stone surface of GRANEX® from excess caulking material, to leave finished work in neat, clean condition with no evidence of spillovers onto adjacent surfaces.

An EPDM type gasket is also available in lieu of a caulked joint. Gaskets come in 3 different profiles and in several colors to match most of the standard aggregates.




Email: sales@grahamfrp.com

GRAHAM FRP Composites

104 Maple Ave.
Inglewood, Ontario, Canada
L0N 1K0

Phone: 1 800 268-7410 or (905) 874-3065

Fax: (905) 838-3386